Wired Flush-mounting Voting System BJ-Q5600

System Overview

BJ-Q5600 voting system offers a wired flushmount conference solution for attendance, voting, election, evaluation and grading.

 

Main features:

◆ Unique computing techniques to ensure flawless accuracy

◆ Multi-level correction and encryption to offer data security

◆ Highly scalable system to support more than 10000 voters

◆ Daisy-chain terminal interconnection for easy cabling

 

Major system component parts:

central control unit, extension unit, flush voting unit, connector(conjuntion box), conference management software, computer and display equipment

 

 

Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~

Iraq Medical Center Olsztyn University, Poland Plenary Hall, City ALICANTE
 

 

Flush Voting Unit BJ-Q5600

The flush voting unit allows the delegate to register attendance and cast a vote for YES/ABST/NO, evaluation and election. Votes are counted automatically and the result is shown on display equipment such as large screen, projector/screen and white board. Results can be printed out or saved in CD.

 

Main Features

◆ Simple and stylish design
◆ LED indicator to show working status for attendance and voting
◆ Voting and evaluation options are defined by system software
◆ 30000V ESD protection circuit design

◆ Waterproof and dustproof design

 

Basic Functions

◆ Utilize unique auto tracking validation and comprehensive calculation technology
◆ Multiple correction and encryption for data process,ensure the data security
◆ Maximum system capacity is 4096 units
◆ Attendance registration: by IC card, key press. Two-color LED indicator to indicate the registration method and status
◆ Voting: Yes/No /Abstain . Vote count and result display are enabled automatically by PC
-- Normal voting and direct voting
-- Single-choice and multiple-choice voting
-- First keypress and final keypress voting
◆ Election: elect one or more out of multiple candidates, with 'competitive election', 'equal number election' and 'quick election’
◆ Evaluation (opinion polls): Best, Good, Fair, Poor. Evaluation method can be defined by the system software
◆ LED indicator will indicate working status of voting, election and evaulation

 

Technical Specifications

Mounting type

flush mounting

Powered

by the central control unit

Weight

0.08Kg

Dimensions

100×40×66mm (W×D×H)

Hole Dimensions

124±4×33±2(L×W)table thickness≥15mm

Working temperature

0 to 45

Storage temperature

-20 to 50

 

 

 

Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*

 

University of Science and

 Technology of China

 

Hall of operational meetings of 

the Academic Council

 

 

 

Ural Institute of state 

fire fighting service,Russia

 

 

Central Control Unit BJ-Z4


Features
♦ Black tempered glass panel design, simple and high-end design. All the function 
divisions are clearly layout and easy to operate.
♦ Built-in DSP processor for acoustic feedback prevention.
♦ Built-in OLCD screen to display system set status.
♦ VOX sensitivity adjustable.
♦ Built-in 4×1 SD video matrix, and support extended HD video matrix.
♦ Supportive SD and HD camera tracking.
♦ Built-in treble/bass compensation for better sound quality.
♦ Support clock and calendar function, 
♦ Support plug-in USB disk for audio recording.

Basic functions 
•In compliance with IEC60914 international standard
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate. 4 route port to connect conference units, the
•system has auto-repair function, sup-port hot plug-and-play.
•One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support upto 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply..
•Built-in auto-detection fo conference units; before conferences, self-test can be run for each conference units
•TCP/IP PC communication between central control unit and PC, which can achieve control management, remote fault diagnosis and remote update.

Extended functions under PC and software control
•ID number writing: the conference system
•supports automatically or manually assign ID to the corresponding equipment.
•Chairman unit can be defined freely, and be able to control the voting process and agenda control.
•Register function and real-time participants statistics
•Voting: Yes, No, Abstain . Vote counting and result display are enabled automatically by PC
Single-choice and multiple-choice voting
First key-press and final key-press voting
•Election: elect one or more out of N candidates, with 'competitive election', 'equal number election' and 'quick election’4-key evaluation: Good, Fair, Poor, Abstain..
•Utilize multi-level error correction and data encryption technique to ensure informa- tion security.
•Support management software dual-system hot backup function; One control computer can be set as backup and connect to the system; if the current computer has faults, the backup computer can be automatically hosted to ensure the smooth and continuous meeting.
•Customized voting options and voting methods, support customized language mode or display screen.
•Conference management software can becustomized.

 

Technical Specifications

Max System Capacity 4096
Standard   Capacity 60~70(different from various models) 
Acoustic Frequency Response 20Hz~20KHz
SNR >96dBA
Channel Isolation >85dB
Dynamic Range >94dB
THD <0.05% AC100~240V,
Power 50/60Hz
Audio Port 1 balanced  (XLR)
2  unbalanced (RCA)
Max Audio Output LINE OUT :+20 dBu unbalanced
BLANCE OUT :+20 dBu balanced
Output Impedance >1KΩ
External Audio Input 0.775V (PHOENIX terminal)
Central Control Method RS-232 
PC Connection Method TCP/IP 
Camera Control Method RS-485
Max Power Consumption 300W
Terminal Connection Port 8-pin×4
13-pin×4 (for TC-Z4,TC-ZB4 only)
6 (for TC-Z4,TC-ZB4 only) 
Display   Screen OLED  (61mm×37mm)
Audio recording port USB (USB:FAT32)
Audio recording File Size 0.8M/m
Active Delegate 1/2/3/4 (not including chairman unit)
VOX   sensitivity H/M/L (76dB/80dB/82dB)
Support Camera Number 4 SD cameras (built-in SD matrix), MAX 8 cameras with extended matrix
Video  Input   Port RCA×4 (1Vp-p 75Ω)
Video Output Port RCA×2 (1Vp-p 75Ω)
Camera Tracking Protocol  PELCO-P/PELCO-D/VISCA
Operating Temperature -0~45℃
Storage Temperature -20~50℃
Dimensions (L*W*H) 485mm×350mm×90mm
Installation Desktop or 19" rack mounting
Weight 7.6Kg
 

 

Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*

 

University of Science and

 Technology of China

 

Hall of operational meetings of 

the Academic Council

 

 

 

Ural Institute of state 

fire fighting service,Russia

 

 

 

Connector CON-5600

The CON-5600 connector is designed to connect control units to function modules including discussion unit, channel selection unit, flush voting unit and/or loudspeaker for power supply and communication signals.

 

Technical Specifications

Working temperature

0~45

Storage temperature

-20 ~ 50

Dimensions (WxDxH)

167x160x40mm

Net weight

1083 g

 

 

 

Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*

 

University of Science and

 Technology of China

 

Hall of operational meetings of 

the Academic Council

 

 

 

Ural Institute of state 

fire fighting service,Russia

 

 

 

 

Extension Unit ZJ-KR

Functions

•Confirm to IEC 60914 international standard.
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
•Three routes 8-pin ports to connect conferenc units, another two route 8-pin port for system cascading.
•Three routes 13-pin ports to connect conferenc units, another two route 13-pin port for system cascading.
•Automatic restoration function: support hot plug and play.
•One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support up to 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply.

Technical Specifications

Max System Capacity 4096
Standard Capacity 60~70(different from various models)
Power AC100~240V,50/60Hz
MAX Power 300W
Terminal Connection Port 8-pin ×5,13-pin×5
Operating Temperature 0~45°C
Storage Temperature -20~50°C
Dimensions (L*W*H) 485mm×350mm×90mm
Installation Desktop or 19" rack mounting
Weight 7.6Kg

 

 

Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*

 

University of Science and

 Technology of China

 

Hall of operational meetings of 

the Academic Council

 

 

 

Ural Institute of state 

fire fighting service,Russia